7. HLZ COMPUTER OPERATION AND PROGRAMMING

7. HLZ COMPUTER OPERATION AND PROGRAMMING

 

Display

Heater Plate

Air Heater

Temperature

Temperature

Switch (4)

Switch (1)

ON/OFF Switch

Check or

 

Program Switch

Down Switch (2)

Up Switch (3)

7. 1 Programming Temperature

You are able to program the setpoint temperature of both the air heater and the heater plate via the computer interface. The heater plate factory default is set to the McDonald’s standard of 160°F. The air heater factory default is set to the McDonald’s standard of 220°F. If the factory default temperature settings are acceptable, skip to Section 7.2, Page 6.

Ensure that the HLZ computer is in the OFF position (nothing in the display).

Press the check switch and enter the code (1,2,3,3). The numerals in the upper right-hand corner represent the key number.

Press Switch (4), then 7. 1 Programming Temperature, Manual background, Manual background, Manual background in order

The display will read SET and the LEDs on both the Heater Plate Switch (1) and the Air Heater Switch (4) will light. Press the switch that corresponds to the heater you wish to program.