Option Installation

7.7Battery Temperature Compensation

For a UPS with external batteries, an optional battery temperature interface optimizes the external battery management by connecting up to four external temperature sensors from the battery cabinets to a control unit inside the UPS.

Figure 47 Multi-temperature sensors

 

Temperature

 

 

 

 

Sensor

 

 

 

+

NC

X103

 

 

IN

12V

 

 

 

-

OUT

 

 

 

 

GND

 

 

 

 

TMP-2

 

 

 

 

Temperature

 

 

 

 

Sensor

 

 

 

+

NC

X104

 

 

IN

12V

 

 

 

-

OUT

 

 

 

GND

 

 

 

 

 

 

 

 

TMP-2

 

 

Monitor

 

 

 

 

Board

 

 

X108

 

– X2

 

Temperature

 

+12V

 

12V

 

 

Sensor

OUT

 

BAT_OUT

 

 

GND

J4

GNDStatic

 

NC

X105

Bypass

+

 

12V

 

 

Module

IN

 

 

OUT

 

 

 

-

 

 

 

GND

 

 

 

 

 

 

 

 

TMP-2

 

 

 

 

 

BCB Control

 

 

 

Temperature

Board

 

 

 

Sensor

 

 

 

+

NC

X106

 

 

12V

 

 

 

IN

 

 

 

-

OUT

 

 

 

GND

 

 

 

 

 

 

 

 

TMP-2

 

 

 

71

Page 81
Image 81
Emerson 115-50/60HZ, 115-120, 15-90KVA, 115-208, 115-600V, 115-480 Battery Temperature Compensation, Multi-temperature sensors

115-600V, 115-208, 115-120, 115-50/60HZ, 115-480 specifications

The Emerson 15-90KVA series is a robust and versatile power solution designed for various applications including commercial, industrial, and data center operations. Operating at voltage ranging from 115 to 480 volts, and supporting frequencies of either 50 or 60 Hz, this series is engineered to meet diverse power requirements.

One of the standout features of the Emerson 15-90KVA is its exceptional reliability and performance under varying load conditions. This power system incorporates cutting-edge technologies that enhance operational efficiency while minimizing downtime. The robust design of the system enables it to maintain optimal performance even in harsh environmental conditions, providing power continuity and safeguarding critical operations.

The Emerson 15-90KVA is equipped with advanced protection mechanisms that ensure the safety of connected equipment. These include overload protection, short-circuit protection, and thermal protection systems, which work together to prevent potential damage from power surges or faults. Moreover, the unit features a user-friendly interface that facilitates easy monitoring and control, enabling operators to track performance metrics and manage power supply effectively.

Another significant characteristic of this power series is its modular design, allowing for scalability and flexibility. Users can easily add or remove capacity based on changing power demands without the need for extensive system overhauls. This scalability makes the Emerson 15-90KVA ideal for growing businesses that require adaptable power solutions.

Energy efficiency is a focal point for the Emerson power series. Utilizing advanced power electronics and intelligent control algorithms, the system minimizes energy losses, ensuring that more power is available for direct usage. This not only reduces operational costs but also aligns with growing sustainability initiatives by lowering the overall carbon footprint.

In summary, the Emerson 15-90KVA series is a high-performance power solution characterized by its reliability, advanced protection features, modular scalability, and energy efficiency. Its versatility across multiple voltage levels and frequency options makes it suitable for a wide range of applications, solidifying its position as a preferred choice in the industry. Whether for industrial facilities, data centers, or commercial spaces, the Emerson 15-90KVA is designed to meet and exceed power demands effectively and efficiently.