Installation Drawings

Figure 39

Outline drawing, Liebert BDC for Liebert® APM, 15-45kVA

 

 

 

 

Cable Entry Area

 

 

23.6" (600)

39.5" (1000)

6.3" (159)

 

 

 

 

X

 

 

 

 

 

Outside Panel

 

 

11.4" x 13.2"

 

 

 

Z

 

 

 

(290 x 335mm)

 

 

 

 

6.5" (164)

 

 

 

 

 

 

 

 

Outside Panel

 

 

 

 

 

 

 

 

 

 

 

 

34.6"

 

Cable Entry Area

 

 

 

 

 

(879mm)

 

 

 

 

 

 

 

11.4" x 13.2"

 

 

 

 

 

 

28.3"

 

 

 

 

 

 

 

 

(290 x 335mm)

78.7"

 

 

 

 

 

(719)

 

 

 

 

 

 

 

 

(2000mm)

 

 

 

 

 

Bracket

 

 

 

 

 

 

6.7" (169)

 

 

 

 

 

 

Centers

 

 

 

 

 

 

Outside Panel

 

 

23.7"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Center

(602)

 

 

 

 

 

 

 

 

TOP

 

5.5" (140)

 

6.4" (162)

 

of

 

 

 

 

 

 

 

Maximum Door

 

 

Gravity

 

 

 

BOTTOM

Outside Panel

 

 

 

Swing: 120°

 

 

 

 

 

 

 

 

 

 

 

NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. All dimensions are in inches [mm].

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

24" (610mm) minimum clearance above unit and

 

 

 

 

 

 

 

 

 

 

 

 

24" (609)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36" (914mm) front access required for service.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leveling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT SIDE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT

 

 

 

 

3.

Keep cabinet within 15° of vertical.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feet

4. Top and bottom cable entryavailable through removable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

access plates. Remove, punch to suit conduit size and replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Control wiring and power wiring must be run

 

Liebert BDC

 

 

 

 

 

 

 

Dimension, in. (mm)

Weight,*

 

 

 

in separate conduits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

Y

 

Z

 

 

6.

Copper cables only are recommended.

 

with Distribution Type

 

 

 

 

 

 

 

 

 

 

 

 

lb (kg)

 

7. All wiring is to be in accordance with national

UAM06008

Without Panelboard

11.8" (300)

 

 

39.4"

 

14.9" (379)

525 (239)

 

 

 

 

and local electrical codes.

 

 

(1000)

 

 

 

 

 

Rev. 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With Panelboard

11.8" (300)

 

 

39.4"

 

14.9" (379)

625 (284)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1000)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Shipping weight, add 150lb. (68kg)

Figure 40

Outline drawing, Liebert BDC for Liebert APM, 15-90kVA

 

 

 

 

 

 

 

 

 

 

 

23.6" (600)

 

 

 

 

6.3" (159)

 

 

 

 

 

X

 

 

 

z

39.5" (1000)

 

Cable Entry Area

 

 

 

 

 

 

 

 

Outside Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11.4" x 13.2"

 

 

 

 

 

 

 

 

 

 

 

(290 x 335mm)

 

 

 

 

 

 

 

 

 

6.5" (164)

 

 

 

 

 

 

 

 

 

 

 

Outside Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

34.6"

 

Cable Entry Area

78.7"

 

 

 

 

 

 

 

(879mm)

 

 

 

 

 

 

 

 

 

11.4" x 13.2" (2000mm)

 

 

 

 

 

 

 

28.3"

 

 

 

 

 

 

 

 

(719)

 

(290 x 335mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bracket

 

6.7" (169)

 

 

 

 

 

 

 

 

 

Centers

 

 

 

 

 

 

 

 

 

 

 

Outside Panel

 

 

 

Center

 

 

 

 

 

 

 

 

 

 

 

 

 

23.7"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of

 

 

 

(602)

TOP

5.5" (140)

 

6.4" (162)

 

Y

 

Gravity

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Door

 

BOTTOM

Outside Panel

 

 

 

 

 

 

 

 

Swing: 120°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES

 

 

 

 

 

24" (609)

Leveling

RIGHT SIDE

1. All dimensions are in inches [mm].

 

 

 

FRONT

Feet

 

 

UAM06010

2. 24" (610mm) minimum clearance above unit and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev. 4

36" (914mm) front access required for service.

 

 

 

 

 

 

 

 

3. Keep cabinet within 15° of vertical.

 

 

 

 

 

 

 

 

 

4. Top and bottom cable entry available through

 

 

 

Dimension, in. (mm)

 

 

removable access plates. Remove, punch to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

suit conduit size and replace.

Liebert BDC with Distribution Type

X

 

Y

 

Z

Weight,* lb (kg)

5. Control wiring and power wiring must be run

No Distribution

 

 

11.8" (300)

39.4" (1000)

14.9" (379)

550 (250)

in separate conduits.

 

 

 

6. Copper cables only are recommended.

With 2-225A Subfeed Breakers

 

11.8" (300)

39.4" (1000)

14.9" (379)

660 (300)

7. All wiring is to be in accordance with national

 

 

 

 

 

 

 

 

 

 

and local electrical codes.

 

With 400A Panelboard

 

11.8" (300)

39.4" (1000)

14.9" (379)

660 (300)

 

 

 

* Shipping weight, add 150lb. (68kg)

 

 

 

 

 

 

 

 

 

 

No Distribution

With 480V Transformer

11 8" (300)

32 7" (830)

24 8" (630)

1522 (692)

62

Page 72
Image 72
Emerson 115-120, 15-90KVA, 115-208, 115-50/60HZ, 115-600V, 115-480 Outline drawing, Liebert BDC for Liebert APM, 15-45kVA

115-600V, 115-208, 115-120, 115-50/60HZ, 115-480 specifications

The Emerson 15-90KVA series is a robust and versatile power solution designed for various applications including commercial, industrial, and data center operations. Operating at voltage ranging from 115 to 480 volts, and supporting frequencies of either 50 or 60 Hz, this series is engineered to meet diverse power requirements.

One of the standout features of the Emerson 15-90KVA is its exceptional reliability and performance under varying load conditions. This power system incorporates cutting-edge technologies that enhance operational efficiency while minimizing downtime. The robust design of the system enables it to maintain optimal performance even in harsh environmental conditions, providing power continuity and safeguarding critical operations.

The Emerson 15-90KVA is equipped with advanced protection mechanisms that ensure the safety of connected equipment. These include overload protection, short-circuit protection, and thermal protection systems, which work together to prevent potential damage from power surges or faults. Moreover, the unit features a user-friendly interface that facilitates easy monitoring and control, enabling operators to track performance metrics and manage power supply effectively.

Another significant characteristic of this power series is its modular design, allowing for scalability and flexibility. Users can easily add or remove capacity based on changing power demands without the need for extensive system overhauls. This scalability makes the Emerson 15-90KVA ideal for growing businesses that require adaptable power solutions.

Energy efficiency is a focal point for the Emerson power series. Utilizing advanced power electronics and intelligent control algorithms, the system minimizes energy losses, ensuring that more power is available for direct usage. This not only reduces operational costs but also aligns with growing sustainability initiatives by lowering the overall carbon footprint.

In summary, the Emerson 15-90KVA series is a high-performance power solution characterized by its reliability, advanced protection features, modular scalability, and energy efficiency. Its versatility across multiple voltage levels and frequency options makes it suitable for a wide range of applications, solidifying its position as a preferred choice in the industry. Whether for industrial facilities, data centers, or commercial spaces, the Emerson 15-90KVA is designed to meet and exceed power demands effectively and efficiently.