PROBLEM

Probable Causes

Corrective Action

 

 

B2.The minimum weight that should

 

 

be programmed is .38 lbs. (.17kg).

ERRATIC BATCH

Continued from previous page.

If a weight less than .38 lbs. (.17kg)

has been programmed and selected,

WEIGHTS ARE

 

the unit will dispense batches of

BEING DISPENSED.

 

 

erratic weights. Verify

(Continued from

 

 

programming in accordance with

previous page.)

 

 

instructions in Chapter 2.

 

 

 

If one of the above actions does not correct

the problem, there may be a problem

 

with the load cell. Call FASC.

 

 

A. Fries in hopper are bridging.

A. Clear bridging (i.e., clumps of fries

 

 

stuck together and forming an arch

 

 

over the drum and/or hopper outlet.

 

B. Improperly positioned drum and/or

B. Verify that the hopper and drum are

 

hopper or improperly positioned

properly installed. If the drum

 

dispense chute.

motor does not engage the drum

 

 

properly, the motor may run, but

DRUM MOTOR RUNS

 

the drum will not turn or may turn

 

erratically.

CONTINUOUSLY

 

 

 

UNTIL UNIT TIMES

 

Verify that the dispense chute is

OUT WITH “CHECK

 

 

properly positioned on the load cell

HOPPER” ERROR,

 

 

arms.

EVEN THOUGH

 

C. Batch weight of 2.25 lbs. (1kg) or

C. The maximum weight that the load

HOPPER APPEARS

FULL OR DISPENSE

greater has been programmed.

cell can measure is 2.25 lbs. (1kg).

 

If a greater weight is programmed

CHUTE IS FULL.

 

 

and selected, the unit cannot

 

 

 

 

“satisfy” the load cell. For best

 

 

operation, the batch weight should

 

 

be kept to 2 lbs. (.9kg) or less.

 

 

Verify programming in accordance

 

 

with instructions in Chapter 2.

 

If one of the above actions does not correct

the problem, there may be a problem

 

with the load cell. Call FASC.

 

 

A. Unit was not in STANDBY mode

A. The CLEAN mode can only be

 

when attempt was made to enter

selected when the unit is in the

 

CLEAN mode.

STANDBY mode.

UNIT WILL NOT GO

 

B. Press the RUN Switch once to

INTO CLEAN MODE.

 

 

place the unit in the STANDBY

 

 

 

 

mode, and then press the CLEAN

 

 

Switch.

 

If the above action did not correct the problem, call FASC.