7.2Installation Specifications
Item |
| Specification |
| |||
|
|
|
|
|
| |
Dimensions (mm) | Depth | Width |
| Height | ||
(Without ADF paper chute) |
|
|
|
| ||
569 (22.4 in) | 302 (11.9 in) |
| 229 (9.0 in) | |||
|
|
|
| |||
|
|
|
|
| ||
Installation Space (mm) | 800 (31.5 in) x 400 (15.8 in) x 450 (17.8 in) |
| ||||
(D x W x H) |
|
|
|
|
| |
|
|
|
|
|
| |
Weight (kg) |
| 8 (17.7 lb) |
|
|
| |
|
|
|
|
|
| |
Input |
| Voltage | 100 to 120 VAC ±10% |
| ||
power |
|
| 220 to 240 VAC ±10% |
| ||
|
|
|
|
|
|
|
|
| Phases |
|
|
| |
|
|
|
|
|
|
|
|
| Frequency | 50 / 60 ± 3Hz |
|
|
|
|
|
|
|
|
| |
Power consumption | 34 W or less |
|
|
| ||
|
|
|
|
|
|
|
ATTENTION
Installation Space is the reference value of an installation space required to read A4 manuscript.
| Item | Specification | ||
|
|
|
| |
Ambient | Device status | Operating | Not operating | |
condition |
|
|
| |
Temperature | 5 to 35 °C (41 to 95°F) | |||
| ||||
|
|
|
| |
| Humidity | 20 to 80 % | 8 to 95 % | |
|
|
|
| |
Heat capacity | 29.3 kcal / H or less |
| ||
|
|
| ||
Shipping Weight (kg) | 11.5 (25.4 lb) |
| ||
|
|
|
|