3.3 Cleaning the ADF
•Pick roller
In step 2, all the Feed rollers turn at the same time. When cleaning the Feed rollers positioned in the lower part of the ADF, be caereful not to touch the other Feed rollers.
Mylar sheet (Transparent)
3
•Feed roller
1)Open the ADF by pushing on the ADF button.
If you open the ADF cover when the indication of the Function No. display is "P" or "0", the Feed rollers do not rotate even you perform the operation of step 2) below. So open the ADF cover when the indication is not "P" or "0".
2)Simultaneously hold down the "Send to" and "Scan" buttons on the operator panel. The Feed rollers start to rotate slowly.
The location of "Send to" and "Scan" buttons are shown in the following illustra- tion.
3)Hold a soft, dry cloth moistened with cleaning fluid against the surface of the rotat- ing Feed rollers so that it lightly cleans the surface of the rollers. Take particular care when cleaning these rollers as black debris matter on these rollers affects doc- ument pick performance.
As a guideline, seven presses of the "Send to" and "Scan" buttons make the Feed rollers to rotate one full turn.
Function No. display
Function
Send to
Scan
Power button
LED
CARE DAILY