Appendix2 DAILY CARE
When operating the scanner, the ADF’s inside glass becomes very
hot.
Before you clean inside the scan- ner, turn off its power and unplug the AC adapter from the outlet. Wait for at least 15 minutes.
Do not turn off the scanner when you clean the Feed rollers or Eject rollers.
■Cleaning MaterialsPart to clean | Standard Cleaning Cycle | |
|
| |
|
| |
Pad ASSY | Clean these parts after every | |
| 5,000 scans. | |
Pick roller | ||
| ||
|
| |
Feed rollers |
| |
|
| |
Plastic rollers |
| |
|
| |
Eject rollers |
| |
|
| |
Sheet guides |
| |
|
| |
Glass |
| |
|
| |
Ultra sonic sensor |
|
Cleaning | Parts No. | Remarks | |
Materials | |||
|
| ||
|
|
| |
|
|
| |
Cleaner F1 | CA99501- | 1 bottle | |
(or isopropyl | 0013 | Moisten a cloth with | |
alcohol) |
| this fluid and wipe the | |
|
| scanner clean. | |
|
|
| |
- Commercially available one | |||
cloth |
|
| |
|
|
|
For details about the cleaning materials, contact the FUJITSU scanner dealer where you purchased the scan- ner.
■Cleaning MethodATTENTION
The scanner must be cleaned more frequently if you scan any of the following type of sheets:
•Documents of coated paper
•Documents that are almost completely covered with printed text or graphics
•Chemically treated documents such as carbonless paper
•Documents containing a large amount of calcium carbonate
•Documents written by pencil
•Documents on which the toner is not fused sufficiently.
For details on the cleaning the ADF, refer to "3.2 cleaning the ADF" in