2.2.1Single-Phase Power Supplies

TABLE 2-4Specifications (Single-Phase Power Requirements) (1 of 2)

 

Power supply

 

 

 

 

 

 

Circuit

 

 

 

 

Power

Apparent

 

Rush

Leak

breaker

 

Voltage

 

Frequency

consumption

power

Power

current

current

capacity

Name

[V]

Phase

[Hz]

[kW]

[kVA]

factor

[A0-p]

[mA]

[A]

 

 

 

 

 

 

 

 

 

 

SPARC

200 to

Single

50/60

10.5 2

11.0 2

0.9 or

100 or

4.1 or

30 7

Enterprise

240

 

+2%, -4%

 

 

higher

less 6

less 6

 

M8000 Server

VAC

 

 

 

 

 

 

 

 

 

±10%

 

 

 

 

 

 

 

 

 

100

 

 

0.1 3

-

-

-

-

-

 

VAC 3

 

 

 

 

 

 

 

 

 

±10%

 

 

 

 

 

 

 

 

SPARC

200 to

 

 

21.3 4

22.4 4

0.9 or

100 or

4.1 or

30 7

Enterprise

240

 

 

 

 

higher

less 6

less 6

 

M9000 Server

VAC

 

 

 

 

 

 

 

 

(base cabinet)

±10%

 

 

 

 

 

 

 

 

 

100

 

 

0.1 3

-

-

-

-

-

 

VAC 3

 

 

 

 

 

 

 

 

 

±10%

 

 

 

 

 

 

 

 

SPARC

200 to

 

 

42.6 5

44.8 5

0.9 or

100 or

4.1 or

30 7

Enterprise

240

 

 

 

 

higher

less 6

less 6

 

M9000 Server

VAC

 

 

 

 

 

 

 

 

(base cabinet +

±10%

 

 

 

 

 

 

 

 

expansion

100

 

 

0.1 3

-

-

-

-

-

cabinet)

 

 

 

VAC 3

 

 

 

 

 

 

 

 

 

±10%

 

 

 

 

 

 

 

 

Power Cabinet

200 to

 

 

21.3 4

22.4 4

0.9 or

100 or

4.1 or

30 7

SPARC

240

 

 

 

 

higher

less 6

less 6

 

Enterprise

VAC

 

 

 

 

 

 

 

 

M9000 Server

±10%

 

 

 

 

 

 

 

 

(base cabinet) 1

 

 

 

 

 

 

 

 

 

Chapter 2 Environmental and Electrical Specifications 2-5