Fujitsu MAF3364FC, MAG3091FC, MAG3182FC manual 7 Service clearance area

Models: MAG3182FC MAF3364FC MAG3091FC

1 107
Download 107 pages 9.99 Kb
Page 55
Image 55
Figure 4.7 Service clearance area

(4)Service clearance area

The service clearance area, or the sides which must allow access to the IDD for installation or maintenance, is shown in Figures 4.7.

Manual background [Surface R]

• Hole for mounting screw

[Surface P]

[Surface Q]

• Cable connection

• Hole for mounting screw

Figure 4.7 Service clearance area

(5)External magnetic field

The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence of the external magnetic field.

(6)Leak magnetic flux

The IDD uses a high performance magnet to achieve a high speed seek. Therefore, a leak magnetic flux at surface of the IDD is large. Mount the IDD so that the leak magnetic flux does not affect to near equipment.

Manual backgroundCAUTION

Damage to drive

A hole or screw portion as shown in Figure 4.8 is used for adjusting air pressure balance between inside and outside the DE. Do not fill with a seal or label.

Seals on the DE prevent the DE inside from the dust. Do not damage or peel off labels.

4 - 8

C141-E078-02EN