Fujitsu MAF3364FC manual 10 AC noise filter recommended 4.3 Connection Requirements, Connector

Models: MAG3182FC MAF3364FC MAG3091FC

1 107
Download 107 pages 9.99 Kb
Page 58
Image 58
Figure 4.10 AC noise filter (recommended)

(5)Noise filter

To eliminate AC line noise, a noise filter should be installed at the AC input terminal on the IDD power supply unit. The specification of this noise filter is as follows:

Attenuation: 40 dB or more at 10 MHz

Circuit construction: T-configuration as shown in Figure 4.10 is recommended.

Figure 4.10 AC noise filter (recommended)

4.3Connection Requirements

4.3.1Connector

Figure 4.11 shows the locations of connector on the interface model.

Interface connector

Figure 4.11 Connector location of SCA2 type interface model

C141-E078-02EN

4 - 11