Fujitsu MAG3182FC, MAG3091FC, MAF3364FC manual ∙ Arre ∙ Tb ∙ Per

Models: MAG3182FC MAF3364FC MAG3091FC

1 107
Download 107 pages 9.99 Kb
Page 71
Image 71

(1)Error recovery parameter

The following parameters are used to control operations such as IDD internal error recovery:

a. Read/write error recovery parameters (page code = 1)

 

Parameter

 

Default value

• ARRE:

Automatic alternate block allocation at read

 

1 (enabled)

 

operation

 

 

• TB:

Uncorrectable data transfer to the INIT

 

1 (enabled)

• EER:

Immediate correction of correctable error

 

1 (enabled)

• PER:

Report of recovered error

 

0 (disabled)

• DCR:

Suppression of ECC error correction

 

0 (Correction is

 

 

 

enabled.)

• Retry count at read operation

63

• Retry count at write operation

0

b. Verify error recovery parameters (page code = 7)

 

Parameter

 

Default value

• ERR:

Immediate correction of recoverable error

 

1 (enabled)

• PER:

Report of recovered error

 

0 (disabled)

• DTE:

Stop of command processing at successful

 

0 (Processing is

 

error recovery

 

continued.)

• DCR:

Suppression of ECC error correction

 

0 (Correction is

 

 

 

enabled.)

• Retry count at verification

63

c. Additional error recovery parameters (page code = 21)

 

Parameter

 

Default value

• RPR:

Report on parameter rounding by mode select

 

0 (disabled)

 

command

 

 

• Retry count at seek error

15

IMPORTANT

1.The user can arbitrarily specify the following parameters according to the system requirements:

ARRE

TB

PER

2.The user also can arbitrarily specify parameters other than the above. However, it is recommended to use the default setting in normal operations.

5 - 12