2.1.3Environmental specifications
Table 2.3 lists environmental and power requirements.
|
| Table 2.3 | Environmental/power requirements | ||||
|
|
|
|
|
|
| |
| Item |
|
|
| Specification | ||
|
| MAT3300NC/NP |
| MAT3147NC/NP | MAT3073NC/NP | ||
|
|
|
| ||||
| Operating |
|
|
| 5 to 55°C | ||
|
|
| |||||
Temperature | Transport |
|
|
| |||
(within a week) |
|
| |||||
(*1) |
|
|
|
| |||
DE surface temperature |
|
| 5 to 60°C | ||||
|
|
| |||||
| at operating |
|
| ||||
|
|
|
|
| |||
| Gradient |
|
|
| 15°C/h or less | ||
| Operating |
|
|
| 5 to 95%RH | ||
|
|
|
|
|
| ||
| Non operating |
|
| 5 to 95%RH | |||
Relative | Transport |
|
|
| 5 to 95%RH | ||
humidity | (within a week) |
|
| ||||
|
|
|
| ||||
| Maximum wet bulb |
| 29°C (no condensation) | ||||
| temperature |
| |||||
|
|
|
|
| |||
Vibration | Operating (*3) | 0.6 mm (5 to 20Hz)/9.8 m/s2 (1G) (20 to 300 Hz) or less | |||||
3.1 mm (5 to 20Hz)/49m/s2 (5G) (20 to 300Hz) or less | |||||||
(*2) |
|
|
|
|
|
| |
Transport (packaged) | 3.1 mm (5 to 20Hz)/49m/s2 (5G) (20 to 300Hz) or less | ||||||
| |||||||
| Operating |
|
| 637.4m/s2 (65G) (2 ms) | |||
Shock (*2) |
| 2205m/s2 (225G) (2 ms) | |||||
| Transport (packaged) |
| 2205m/s2 (225G) (2 ms) | ||||
Altitute | Operating |
| |||||
(above sea |
|
|
|
|
|
| |
level) | |||||||
|
| Ready |
|
| 0.6 A | ||
|
| (Average) |
|
| |||
|
|
|
|
|
| ||
|
| Peak within |
|
|
|
| |
| +12 VDC | 100 ∝ s at |
|
| 3.0 A | ||
| ±5% |
|
|
|
| ||
Power | Random |
|
|
|
| ||
|
|
|
|
| |||
| W/R |
|
| 1.0 A | |||
requirements |
|
|
| ||||
| (about 80 |
|
| ||||
Input power |
|
|
|
|
| ||
| IOPS) |
|
|
|
| ||
(*5) |
|
|
|
|
|
| |
| Ready |
|
| 0.46 A | |||
|
|
|
| ||||
| +5 VDC | Random |
|
|
|
| |
| W/R |
|
|
|
| ||
| ±5% (*6) |
|
| 1.0 A | |||
| (about 80 |
|
| ||||
|
|
|
|
|
| ||
|
| IOPS) |
|
|
|
| |
| Ripple (*7) |
| +5 V/+12 V 250 | ||||
|
|
|
|
|
|
|
(*1) For detail condition, see Section 4.1.
(*2) Vibration applied to the drive is measured at near the mounting screw hole on the frame as much as possible.
(*3) At random seek write/read and default on retry setting with log sweep vibration.
|