4.1.2Mounting

The permissible orientations of the IDD are shown in Figure 4.3, and the tolerance of the angle is

±5° from the horizontal plane.

(a) Horizontal –1

(b) Horizontal –2

(c) Vertical –1

(d) Vertical –2

(e) Upright mounting –1

(f) Upright mounting –2

Direction of gravity

Figure 4.3 IDD orientations

(1)Mounting frame structure

Special attention must be given to mount the IDD disk enclosure (DE) as follows.

a)Use the frame with an embossed structure, or the like. Mount the IDD with making a gap of 2.5 mm or more between the IDD and the frame of the system.

b)As shown in Figure 4.4, the inward projection of the screw from the IDD frame wall at the corner must be 5.0 mm or less.

c)Tightening torque of screw must be secured with 0.59N·m (6kgf·cm) ±12%.

4-4