Fujitsu MAT3300NC/NP, MAT3073NC/NP, MAT3147NC/NP manual Write Write Extend, Format Unit

Models: MAT3300NC/NP MAT3147NC/NP MAT3073NC/NP

1 130
Download 130 pages 52.93 Kb
Page 48
Image 48

Automatic alternate block allocation at write operation

If AWRE flag in the MODE SELECT parameter permits the automatic alternate block allocation, the IDD executes two kinds of automatic alternate processing during WRITE command processing as described below:

Type 1 (Reassignment of Uncorrectable Read Error)

1)Commands to be applied

-WRITE

-WRITE EXTEND

-WRITE at executing WRITE AND VERIFY

2)Application requirements

When any of the above commands is issued to LBA registered in the uncorrectable error log of the READ command (LBA log of uncorrectable error while the READ command is executed), the AWRE processing is applied.

3)AWRE processing

The following processings are performed when the LBA matches the one in the uncorrectable error log:

a)Primary media check

-Creates an uncorrectable error pattern (invalid LBA pattern) in the position of the error LBA, repeats the primary media check up to three times. If the error still occurs after the check repeated three times, it is judged to be defective. Then, it performs the alternate processing.

b)Alternate processing

-Alternate media check

Writes the data that causes an unrecoverable error into the alternate block, and performs the media check.

(If the alternate block is a defective sector, the block is registered to the G list, another alternate block is allocated.)

c)SA and defect map update processing (on alternate side)

When an error occurs in the alternate processing, this WRITE command terminates with error.

When the alternate processing normally terminates, the WRITE command is executed.

Depending on the alternate processing result, one of the following additional sense codes is returned:

Alternate processing is succeeded: 01-OC-01

Type 2 (Reassignment of write fail sector)

1)Commands to be applied

-WRITE command

-WRITE EXTENDED command

-FORMAT UNIT

2)Application requirements / processing

When WRITE/WRITE EXTENDED command detects any Servo error (e.g. Write offtrack error) and cannot be recovered within pre-determined retry number (specified in Mode Parameter). For the sectors around defective Servo, alternate blocks are allocated and the data of this WRITE commands are re-written.

3-14

C141-E201

Page 48
Image 48
Fujitsu MAT3300NC/NP, MAT3073NC/NP, MAT3147NC/NP manual Write Write Extend, Format Unit