Interface
5-106 C141-E104-02EN
5.5.6 Series termination required for Ultra DMA
Series termination resistors are required at both the host and the device for
operation in any of the Ultra DMA Modes. The following table describes
recommended values for series termination at the host and the device.
Table 5.17 Recommended series termination for Ultra DMA
Signal Host Termination Device Termination
DIOR-:HDMARDY-:HSTROBE 22 82
DIOW-:STOP 22 82
CS0-, CS1- 33 82
DA0, DA1, DA2 33 82
DMACK- 22 82
DD15 through DD0 33 120 (100 MHz)
DMARQ 82 22
INTRQ 82 22
IORDY:DDMARDY-:DSTROBE 82 22
Note: Only those signals requiring termination are listed in this table. If a signal is
not listed, series termination is not required for operation in an Ultra DMA Mode.
For signals also requiring a pull-up or pull-down resistor at the host see Figure 5.9.
Figure 5.9 Ultra DMA termination with pull-up or pull-down
Configuration of cable
For the configuration of the cable (common use of primary port and secondary
port), DMACK signal should not be used in common. It is not recommended to
use DIOR-, DIOW- and IORDY signal in common.
Vcc
DMARQ
IORDY