Fujitsu MPF3XXXAH manual

Models: MPF3XXXAH

1 191
Download 191 pages 9.19 Kb
Page 117
Image 117

The host can predict failures in the device by periodically issuing the SMART Return Status subcommand (FR register = DAh) to reference the CL and CH registers.

If an attribute value is below the insurance failure threshold value, the device is about to fail or the device is nearing the end of it life . In this case, the host recommends that the user quickly backs up the data.

At command issuance (I-O registers setting contents)

1F7H(CM)

1

0

1

1

0

0

0

0

 

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

DV

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

Key (C2h)

 

 

 

1F4H(CL)

 

 

 

Key (4Fh)

 

 

 

1F3H(SN)

 

 

 

 

xx

 

 

 

1F2H(SC)

 

 

 

 

xx

 

 

 

1F1H(FR)

 

 

 

Subcommand

 

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (I-O registers setting contents)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

 

DV

 

xx

 

 

 

 

 

 

1F5H(CH)

 

Key-failure prediction status (C2h-2Ch)

1F4H(CL)

 

Key-failure prediction status (4Fh-F4h)

1F3H(SN)

 

 

 

 

xx

 

1F2H(SC)

 

 

 

 

xx

 

1F1H(ER)

 

 

 

Error information

 

 

 

 

 

 

 

 

 

5 - 50

C141-E106-01EN

Page 117
Image 117
Fujitsu MPF3XXXAH manual