(4)Ambient temperature

The temperature conditions for a disk drive temperature at a point 3 cm from the disk drive. surface temperature from exceeding 60°C.

mounted in a cabinet refer to the ambient Pay attention to the air flow to prevent the DE

Provide air circulation in the cabinet such that the PCA side, in particular, receives sufficient cooling. To check the cooling efficiency, measure the surface temperatures of the DE. Regardless of the ambient temperature, this surface temperature must meet the standards listed in Table 3.1. Figure 3.6 shows the temperature measurement point.

1

Figure 3.6 Surface temperature measurement points

Table 3.1 Surface temperature measurement points and standard values

No.

Measurement point

Temperature

1

DE cover

60°C max

3 - 6