224
Chapter 9 Operation and Maintenance
If the extension cable is unplugged from the baseboard connector
Connect the cable by referring to the following table.

SCSI Devices

The unit does not operate properly.
Refer to "Connection via the SCSI Card" of "7.7 Connection of Optional Devices" (pg.187).
Check to see whether the cable is connected properly. If it is not connected, correctly connect the
cable.
Check to see whether the jumper pins are set correctly. If not, correctly set the jumper pins.
Check to see whether the SCSI-ID and terminator are set correctly. If not, correctly set the SCSI-ID
and terminator.

Others

Notes on Operations in RAID1 Configuration
When disks of the server are used in RAID1 redundancy configuration, the disk data is protected even if
a single hard disk unit has failed. However, if both hard disks have failed, the disk data will be
permanently lost. Also, if the user repeatedly powers on/off or repeatedly reboots while a single disk unit
has failed, data reliability may be lost.
If a disk failure is detected, replace the failed disk unit as soon as possible to safeguard customer data.
table: Fan Connector List
Fan number Fan connector
number
Fans 1 and 2 CN6
Fans 3 and 4 CN7
Fans 6 and 7 CN9
[Inside the server]
CN9
CN7
CN6 Extension cable
Extension cable
Baseboard
Fan 1 Fan 2 Fan 3
Fan 6 Fan 7
Fan 4