ATTENTION

Make sure that the Pad ASSY is firmly

 

 

secured. If it is not secured, documents will

 

jam or other feeding errors may occur.

5. Close the ADF

ADF

ÖGently push the ADF until you hear it click when returning it to its original position.

6.Turn on the scanner.

ÖThe ScanSnap Manager icon changes from the

inactive state to the active state.

7.Click and hold down the mouse button on the

"ScanSnap Manager" icon in the Dock menu, and select [Check consumable supplies] from the pop-up menu.

8.In the “Check consumable status” window, click the [Reset] button of the consumable you replaced.

ÖA confirmation pop-up screen appears.

ÖIf you click the [Yes] button, the counter is reset to “0.”

6.3. Replacing the Pick Roller

Replace the Pick roller following the procedures below.

1.Remove the document on the Paper chute if any.

2.Pull the Cover open lever and open the ADF.

Paper chute

ADF

Cover open lever

3. Adjust the Side Guide to the “A5” size.

A5

A5

4. Pinch the handle on the Sheet guide to remove it.

Sheet guide

Handle

Claw

5.Rotate the Pick roller bushing (Left) in the direction of the arrow.

Pick roller

Pick roller bushing

Pick roller shaft

ScanSnap S500M for Macintosh Getting Started 15