6. Consumables/Carrier Sheet
This chapter describes how to replace and purchase consumables and regular replacement parts.
WARNING
Fire/Electric Shock
Before you replace the consumables, disconnect the AC adapter from the power outlet to turn off the scanner.
6.1.Part Numbers and Replacement Cycle of Consumables
The following table lists the part numbers of consumables and shows rough guidelines for replacing these parts.
No. | Description | P/N | Replacement Cycle | |
1 | Pad ASSY | 50,000 scan or one | ||
year | ||||
|
|
| ||
2 | Pick roller | 100,000 scans or | ||
one year | ||||
|
|
|
These replacement cycles are rough guidelines when A4/Letter
6.2. Replacing the Pad ASSY
Replace the Pad ASSY following the procedure below.1.Remove the documents on the Paper chute.2.Open the ADF while pulling the Cover open lever.Paper chute
ADF
Cover open lever
3.Remove the Pad ASSY.Pull out the Pad ASSY in the direction of the arrow while pinching both ends of the Pad ASSY.
HINT
To estimate when the consumables will have to be replaced and to get an overlook of the already scanned pages, refer to the following:
1.
2.Click [Check consumable supplies] at the menu.
(The window ("Check consumable status" screen) that indicates how many times consumables have been used will be displayed.
Replace the consumables referring to "Target value to change supplies" as a rough guideline.
For details about consumables and where to purchase them, visit the following Website or contact the Fujitsu scanner dealer where you purchased your scanner.
[Website] http://scansnap.fujitsu.com/
Pad ASSY
ADF
4.Attach the new Pad ASSY.Pad ASSY
ADF
Make sure that the Pad ASSY is completely attached. Otherwise, document jams or other feeding errors may occur.
ScanSnap S510 Getting Started 25