5.Close the ADF.
ADF
You should hear the ADF click when it returns to its original position.
6.Turn on the scanner.
ScanSnap Manager icon changes from to S .
7.
8.In the "Check consumable status" window, click the [Reset] button of Pad ASSY Count.
The counter is reset to "0".
6.3. Replacing the Pick Roller
Replace the Pick roller following the procedure below.
1.Remove the document on the Paper chute.
2.Open the ADF while pulling the Cover open lever.
Paper chute
ADF
Cover open lever
26
3.Adjust the Side guide to the "A5" size.
A5 | A5 |
4.Remove the Sheet guide.
Pinch the Pickup tabs on the Sheet guide to pull the Sheet guide to remove it.
Sheet guide | Pickup tab |
5.Rotate the Pick roller bushing (left side) in the direction of the arrow.
Pick roller
Pick roller bushing
Pick roller shaft
6.Remove the Pick roller with its shaft.
Slightly pull up the left part of the Pick roller shaft (about 5mm), move it towards the left side, and then raise it to remove from the scanner.
Pick roller shaft
Pick roller