50 SPARC Enterprise T1000 Server Installation Guide • April 2007
netsc_ipnetmask – Netmask for the system controller subnet
Note – For more information on configuring ALOM CMT,refer to the Advanced
Lights Out Management (ALOM) CMT Guide.
Toconfigure these parameters you must use the setsc command. The usage is:
1. Set the netmask for the system controller.
This example uses 255.255.255.0 to set the netmask. Yournetwork environment
subnet might require a differentnetmask. Use a netmask number most appropriate
to your environment.
2. Set the IP address for the system controller.
3. Set the IP address for the system controller gateway.
4. Set the if_network parameter to true.
5. Use the showsc command to verify that the parameters were set correctly.
The showsc command displays all the configuration parameters and their values, as
shown in the example below.
sc> setsc parameter
sc> setsc netsc_ipnetmask 255.255.255.0
sc> setsc netsc_ipaddr service-processor-IPaddr
sc> setsc netsc_ipgateway gateway-IPaddr
sc> setsc if_network true