Chapter 3 Powering On the System 33
a. Set the IP address for the system controller.
b. Set the IP address for the system controller gateway.
c. Set the netmask for the system controller.
This example uses 255.255.255.0 to set the netmask. Yournetwork environment
subnet might require a differentnetmask. Use a netmask number most appropriate
to your environment.
6. Use the showsc command to verify that the parameters were set correctly.
sc> setsc netsc_ipaddr service-processor-IPaddr
sc> setsc netsc_ipgateway gateway-IPaddr
sc> setsc netsc_ipnetmask 255.255.255.0
sc> showsc
Advanced Lights Out Manager CMT v1.x
parameter value
--------- -----
if_network true
if_connection ssh
if_emailalerts false
netsc_dhcp true
netsc_ipaddr xxx.xxx.xxx.xxx
netsc_ipnetmask 255.255.255.0
netsc_ipgateway 0.0.0.0
mgt_mailhost
mgt_mailalert
sc_customerinfo
sc_escapechars #.
sc_powerondelay false
sc_powerstatememory false
sc_clipasswdecho true
sc_cliprompt sc
sc_clitimeout 0
sc_clieventlevel 2
sc_backupuserdata true
diag_trigger power-on-reset error-reset