Activating IORSF | Standard processing in SVP mode |
6.5.2 Activating IORSF
The set IORSF must be activated with a IMPL:
Conditions
You must be in the AUXILIARY FRAME: IORSF CONTROL screen.
ÊPress P3 to switch back to the AUXILIARY FRAME: MENU.
Ê Enter 4 in the SELECTION=> field. Press ENTER .
The AUXILIARY FRAME:
E02L01F |
FUNCTION=>
*1 POWER OFF
*2 IMPL
RUN | ||
|
| M |
|
| FLAG CODE = F6C0C100 00000F00 |
LTG |
| TAST |
Figure 39: AUXILIARY FRAME : P-OFF/IMPL screen
Ê Enter 2 in the FUNCTION=> field to execute an IMPL. Then press ENTER .
The following prompt appears:
***********************************
* | * |
* ARE YOU SURE ? (ENTER Y OR N) N * | |
* | * |
***********************************
!
The IMPL must not be executed during system operation!
Ê Press Y to execute the IMPL or N , to cancel the procedure. Confirm your entry with
ENTER .
80 |