2. WIRING

2.2Wiring Optional Equipment

Navigator

Use cable type MJ-A6SPF0011/0012 (option) to connect the navigator to the NMEA connector.

Water temperature sensor T-02MSB, T-02MTB, T-03MSB

Connect the water temperature sensor cable to the TEMP connector.

2.3Input/Output Sentences

Input sentences

Sentence

Data

Remarks

 

 

 

BWC

Range/bearing to waypoint

 

 

 

 

GGA

Time, position

 

 

 

 

GLC

GRI, TD (Loran C)

 

 

 

 

GLL

Latitude and longitude

 

 

 

 

GTD

TD (Loran C)

 

 

 

 

MTW

Water temperature

 

 

 

 

RMA

Latitude and longitude, TD, ground speed and course by a LORAN-C receiver

 

 

 

 

RMB

Recommended minimum navigation information

 

 

 

 

RMC

Latitude and longitude, speed over ground and course over by a GPS

 

 

 

 

VHW

True/magnetic bearing, speed through water

Great circle

 

 

 

VTG

Speed through the ground and course

 

 

 

 

XTE

Cross track error

 

 

 

 

Output sentences

Sentences

Talker

Data

Remarks

 

 

 

 

DBS

SD

Depth below sea surface

Ver. 1.5

 

 

 

 

DBT

SD

Depth below transducer

Ver. 1.5

 

 

 

 

DPT

SD

Depth below transducer

Ver. 2.0

 

 

 

 

MTW

YC

Water temperature

Ver. 1.5 Ver. 2.0 with connection of water

 

 

 

temperature sensor

 

 

 

 

TLL

SD

Marker line position

Ver. 2.0

 

 

 

 

VRM

SD

VRM depth

 

 

 

 

 

VHW

VW

Ship’s speed

 

 

 

 

 

2-3

Page 25
Image 25
Furuno B042-016, B042-004, B042-008 manual Wiring Optional Equipment, Input/Output Sentences