1. MOUNTING

Thru-hull mount water temperature sensor T-02MSB, T-03MSB

Select a suitable mounting location considering the following points:

Select a mid-boat flat position. The sensor does not have to be installed perfectly perpendicular; however, the location should not be such that the transducer may be damaged when the boat is dry-docked.

Locate away from equipment which gives off heat.

Locate away from drain pipes.

Select a location where vibration is minimal.

T-02MSB

T-03MSB

Sensor Holder

Sensor

 

 

 

 

cable

 

 

Locknut

 

Locknut

 

 

 

 

 

 

 

Washer

 

 

 

 

Gasket

 

 

Locknut

 

 

 

 

 

φ 21 mm

 

 

Washer

 

 

 

Gasket

 

 

 

 

 

 

 

φ 25 mm

 

Coat with

 

 

 

 

sealant.

 

 

 

 

 

 

Coat with

 

 

 

sealant.

 

Mounting procedure

 

 

 

Plate thick-

 

Holder Guide

 

ness within

1. Drill a hole of 21 mm in diameter in

 

 

 

 

 

25 mm

the mounting location.

 

 

 

Mounting procedure

 

2. Pass the sensor cable through the

 

1. Drill a hole of 25 mm in diameter in the mounting

hole.

 

location.

 

3. Pass gasket, washer and locknut

 

 

2. Coat holder guide with high quality sealant, and

onto cable in that order.

 

pass gasket, washer and locknut onto holder

4. Coat the sensor flange with high

 

 

guide in that order and then tighten the locknut.

quality sealant and then fasten the

 

3. Set the sensor holder to the holder guide from

sensor with the locknut.

 

inside the boat and then tighten the locknut.

(Torque: max. 59N·m)

 

4. Launch the boat to check for water leakage

5. Launch the boat to check for water

 

around the sensor.

 

leakage around the sensor.

 

 

 

 

 

 

Assembling thru-hull water temperature sensor T-02MSB, T-03MSB

1-5

Page 21
Image 21
Furuno B042-004, B042-016, B042-008 manual Thru-hull mount water temperature sensor T-02MSB, T-03MSB