Furuno CH-37 manual Motion Sensor MS-100 Option, External Interface Option, Mounting procedure

Models: CH-37

1 71
Download 71 pages 57.02 Kb
Page 25
Image 25

1.5Motion Sensor MS-100 (Option)

The MS-100 measures ship’s pitching and rolling angles with sensors using the principles of the gyroscope. The MS-100 is free from error caused by ship’s ver- tical and horizontal motion. Therefore, it can be installed at any convenient loca- tion. However, ship’s semi-permanent inclination due to loading imbalance cannot be detected. Compensate for this as described in Chapter 3.

Mounting considerations

• Vibration in the mounting area should be FORE

minimal.

θ ≤ 5°

 

• Locate the unit away from areas subject

 

to water splash.

 

• The ambient temperature should not ex-

AFT

 

ceed 50°C.

 

Figure 1-18 Motion sensor MS-100

Mounting procedure

Orient the FORE mark on the unit toward the ship’s bow and mount the unit level to within 5° in all directions.

1.6External Interface (Option)

This section shows how to install External E/S Interface (type OP06-13) and/or the External Monitor Interface (type OP06-14).

For connecting external monitor, prepare mini D-SUB 15 pin cable (male-male).

Recommended cable : EVNPSO5-50ft, manufactured by Black Box Japan Co.,Ltd.

External monitor interface installation kit

Part

Type, Q'ty

Code No.

Q'ty

 

 

 

 

External Monitor Interface Assy.

-

-

1

 

 

 

 

XH Connector Assy.

06-313 (13-13P)

006-550-840

1

 

 

 

 

Screw

M3x6

000-881-103

4

 

 

 

 

Screw

M3x8

000-881-404

1

 

 

 

 

Cable Ties

No.249

000-515-871

1

 

 

 

 

1-15