Priority setup

1.Press ▲ or ▼ to choose SET PRIORITY at the SET I/O PORT sub-menu and press the [ENT] key.

[SET PRIORITY] L/L, COG, SOG

HDG

ROT

QUIT [MENU]

PRIORITY menu

2. "L/L, COG, SOG" is selected; press the [ENT] key.

[SET L/L, COG, SOG] COM4: 1

COM5: 2

COM6: 3

QUIT [MENU]

3. COM4 is selected; press the [ENT] key to display the setting window.

1

2

3

4.Choose the priority level for the COM4 port (position, course over ground and speed over ground data) and press the [ENT] key.

"1" is the highest and "3" is the lowest.

5.Set the priority of COM5 and COM6 similarly.

Note: Do not set same number among COM4, COM5 and COM6.

6.Press the [MENU] key to return to the SET PRIORITY menu.

7.Press ▲ or ▼ to choose HDG and press the [ENT] key.

8.Set the priority for heading data similar to how you did for “L/L, COG, SOG”.

9.Press ▲ or ▼ to choose ROT and press the [ENT] key.

10.Set the priority for rate-of-turn data similarly.

11.Press the [MENU] key several times to save the settings.