13. MAINTENANCE & TROUBLESHOOTING

13.2Replacement of Fuse, Battery

The fuse on the power cable protects the system from reverse polarity of the ship’s mains and equipment fault. If the fuse blows, find the cause before replacing it. Use only a 3 A fuse. Using the wrong fuse will damage the unit and void the warranty.

CAUTION

Use the correct fuse.

Use of a wrong fuse can cause fire or damage the equipment.

A battery installed on the circuit board inside display unit preserves data when the power is turned off. The life of the battery is about three years. When the battery voltage is low the battery icon () appears on the display. When this happens, contact your dealer to request replacement of the battery.

 

Type

Code Number

 

 

 

Lithium

CR2450-F2 ST2L

000-144-941

Battery

 

 

Note : Use only the specified battery. Use of an incorrect battery may cause explosion. Dispose of the battery in accordance with local regulations.

 

13.3 Simple Troubleshooting

 

Below are simple troubleshooting

 

procedures which the user can follow to

 

restore normal operation.

Simple troubleshooting (plotter)

If …

Then …

 

check for blown fuse.

 

 

 

check that the power connector is firmly tightened.

you cannot turn on the power

 

check for corrosion on power cable connector.

 

 

 

check for damaged power cable.

 

 

 

check ship’s battery for proper voltage output (12/24 V).

 

 

power is on but nothing appears

press the [POWER/BRILL] key and then the cursor pad

to adjust display brilliance and tone.

 

 

 

there is no response when a key is pressed

turn on the power again.

 

 

position is not fixed within 90 seconds.

check for loosened antenna connector.

 

check GPS receiver status indication.

 

 

 

track is not plotted

plotting is stopped. (“H” appears on the plotter display.)

 

 

bearing is wrong

check that correct magnetic variation is entered on the

DISPLAY OPTIONS menu.

 

 

 

loran or Decca TDs do not appear

check that proper Loran or Decca chain codes are

entered on the DISPLAY UNIT.

 

 

 

loran TDs are wrong

enter TD offset on the GPS/DGPS/TD OPTIONS menu.

 

 

ship’s speed display is not zero after ship is stopped

try to decrease GPS speed smoothing setting on the

GPS/DGPS/TD OPTIONS menu.

 

 

 

13-2