1. INSTALLATION

Flush mounting

Note: Use supplied pan head screws when the thickness of the bulkhead is from 11 to 14

mm.For bulkhead which exceeds 14 mm in thickness the length of the pan head screws should be bulkhead thickness plus 7.3±1.5 mm. Also the length of B should max. 7mm.

B A

1.Prepare a cutout in the mounting location whose dimensions are as shown on the next page.

2.Fix the display unit by six pan head screws M4 X 20. Refer to the outline drawing on page D-2.

6-R2.25

Pan head screws

0.5

 

0.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

147

 

89

 

 

 

 

 

 

 

Flush mount

242 0.5

4.5

244

 

 

 

1

50

15 0.5

238 1

(Cutout for flush mount)

143 1

Flush mounting of display unit

3

Page 11
Image 11
Furuno GP-1850WD installation manual Flush mounting of display unit