4. INCORPORATION OF DGPS BEACON RECEIVER KIT (for GP-1850W)

Handling of Coaxial Cable

Do not touch the connector with bare hands; use gloves.

Use radio pincers to remove, and pull out straightly.

Plug in connector straightly.

3.Fasten the GR-7000A (DGPS beacon receiver) to the heat sink with four 3X8 screws as shown in the figure below.

Screws (3 X 8), 4pcs.

DGPS beacon receiver

GR-7000A

GN-8091

Installation of DGPS beacon receiver

4. Open the cover of GR-7000A to connect two coaxial cables shown below.

J2

J1

Mini pin coax. cable

J3

Piece of shrink tubing

From GN-8091

Cable assy.

S.FL2-2LP0.7-D-WHT (250) (Supplied with DGPS kit)

Connecting the coaxial cables in GR-7000A