2.WIRING

All wiring are terminated at the rear of the display unit.

Display unit

Antenna unit

GPA-019

GPA-017

(GP-1850W)

(GP-1850WD)

 

Earth terminal

Ground

 

 

 

 

 

+ GND

 

 

 

 

 

1

3

 

 

 

 

 

 

2

 

 

 

 

 

 

-

ANT

XDR

TEMP/SPD

DGPS

NMEA

12

- 24

VDC

 

 

 

 

 

External equipment

DGPS beacon receiver

(option for GP-1850W, Black White

RS-232C only)

Shield

 

Display unit, rear view

Power cable

Connect the power cable to the power connector. Connect the leads to the battery (12 or 24 VDC); white to plus(+) terminal and black to minus(-) terminal.

Cable connector

Power cable w/fuse (5A)

Lead wire

Black White

BATTERY

Connecting the power cable to the battery