5. INSTALLATION

WARNING

ELECTRICAL SHOCK HAZARD

Do not open the equipment unless totally familiar with electrical circuits and service manual.

Only qualified personnel should work inside the equipment.

5.1 Mounting

5.1.1 Mounting location

The mounting location should satisfy the following requirements:

The mounting location should be clean, moderate in temperature and humidity and well ventilated.

Be sure to leave sufficient space around the unit for maintenance and checking.

A magnetic compass will be affected if placed to close to the IB-681. Observe the fol- lowing compass safe distances to prevent deviation of a magnetic compass: Standard compass, 1.2 m, Steering compass, 0.9 m.

Keep the unit out of direct sunlight because of heat that can build up inside the cabinet.

5.1.2 Mounting procedure

The unit can be mounted on a tabletop. Fix the unit to the chosen location with 6x20 tapping screws (supplied). For added support, used M6 bolts (local supply) instead of the tapping screws.

Note: Do not place the unit atop the terminal unit of the FELCOM 81.