2.WIRING
Open the IF unit with your hands, detach the shield cover and connect external equipment, refer- ring to the illustration below and the interconnection diagram. Cables are mainly connected to the unit with WAGO connectors. See the instructions below for how to attach wiring to the connectors. The opener for the WAGO connectors is attached to the inside of the inner cover. Fix cables to their respective cable posts with cable ties (supplied). Run a ground wire
Cable post
J3 | J4 (NMEA 0183) | J5 (NMEA 0183) | J7 | J8 (Analog) | Power cable | Ground terminal |
|
|
|
|
|
|
|
Recommended Cables |
|
|
|
|
|
|
|
|
|
|
|
|
|
Power cable: AWG
All other cables: AWG
* Japan Industry Standard cable
How to wire WAGO connector
How to fix cable to cable post
Twist
Wire
1. Insert opener.
2. Press opener.
3. Insert core.
4. Release opener.
Opener
Fix cable to cable post with two cable ties (supplied).
Cable post
Cable tie
2