3.2 RGB Adjustment

Color may be adjusted with the following potentiometers. Turn the potentiometers clockwise to increase color.

Model

Potentiometer Setting

FCV-1200 Series, CH-250,

Default setting

FR-1760DS

 

GD/GP-280/380/680, FCV-1500

Fully clockwise

Series, CH-37, CSH23/73/83,

 

FR-1500 MK3 Series

 

R1: Red

 

R2: Green

 

R3: Blue

 

3.3 Brilliance Adjustment

Brilliance can be adjusted from the control unit of the FCV-1200 series or CH-250 by setting jumper block J17 as below.

J17: Brilliance control circuit selection

1-2: Brilliance is adjusted from the MU-150C (default setting)

2-3: Brilliance is adjusted from the control unit of the FCV-1200 series or CH-250

Note: Do not change the setting of the J16 or J18. The default setting for both is “1-2”.