Garland Broiler operation manual CARE & CLEANING continued

Models: Broiler

1 24
Download 24 pages 56.6 Kb
Page 10
Image 10
CARE & CLEANING continued

CARE & CLEANING continued

On a single broiler unit the grease drawer is located inside the valve panel. On a double broiler the grease from the upper broiler section drains into a container suspended from the front of the unit. The grease from the lower broiler section drains through the hopper into a grease drawer located inside the valve panel.

Remove and clean the grid rack inserts and grease drip chute daily. Pull the grid rack forward and lift the grease rack insert out of the frame. Remove the grease drip chute by pulling it forward out of the rack frame guides.

Instructions For Removal Of

Grid Rack & Grid Rack Frame

Remove the broiler grid racks as follows:

1.Bring the grid rack down to the lowest adjustment position.

2.Pull the entire grid rack out of the broiler as far as possible.

3.Remove grid rack grease drip chute (located below wire rack) by grasping hold of the chute and pulling forward out of the frame guides.

4.Remove wire racks by lifting the front of each wire rack over the rack front plate.

5.Pull the empty grid rack frame assembly as far forward as possible (until the stops hit the front of the carriage assembly), lift up on the handle and pull the rack frame forward so the stops clear the carriage assembly. Continue pulling the rack frame forward until the rear bearings reach the notches in the carriage tracks and lift the rear of the rack up and out of the carriage; the entire frame is now free from the unit.

6.Place the rack raising lever in the highest position for safety purposes.

Before cleaning the hopper, replace the grease drawer to receive any drippings and solid particles freed by the cleaning. The additional internal grease diverter should be removed from the top section and cleaned at this time. The diverter is removed by raising the rack assembly and lifting up the front of the diverter. After disengaging the screws at the front of the unit, pull the diverter forward and remove from the unit.

Carriage mechanisms should be kept clean, particularly around the roller bearings. If the roller bearings have been washed clean or appear to be dry, they should be lubricated using salt-free vegetable oil or a non-toxic high temperature bearing lubricant.

Infra-Red Burners must be cleaned periodically by a service professional.