Magnum 500-Series Switching Hubs

Installation and User Guide (08/98)

 

 

cable distance is only limited by the physical layer line driver and cable attenuation. There are no collision-domain restrictions or limitations.

The Magnum 500-Series Switching Hubs perform half- or full-duplex mode auto-negotiation independently on all eight 10Mb switched ports. If the device or node on the other end of a port’s attached cable supports F/H mode auto-negotiation or is set to operate as full-duplex, the Magnum 500’s 10Mb port will negotiate to run full-duplex. If the attached device or node doesn’t support F/H mode auto-negotiation (for example, if it is a 10Mb repeater or a standard 10Mb hub), the Magnum 500’s 10Mb ports will default to operate at half-duplex.

If needed to extend to a greater distance than the 100 meters available with twisted pair cabling, an external 10Mb fiber Media Converter unit can be used to convert the cable to fiber. Fiber cable at 10Mb can run up to 2Km with multi-mode fiber and 15Km with single-mode fiber, either half- or full-duplex. (At 100Mb speed, fiber cable can achieve these distances only in the full-duplex mode).

4.6Collision-based Flow-control

Magnum 500 series switches incorporate a collision-based flow-control mechanism. The purpose of flow-control is to reduce the risk of data loss if a long burst of activity causes the switch to backlog frames until its memory is fill up. This is most likely to occur when data is moving from a 100Mb port to a 10Mb port, and the speed difference makes the 10Mb port unable to keep up. It can also occur when multiple 10Mb ports are attempting to transmit to one 10Mb port, and in other protracted heavy traffic situations.

The switch is constantly monitoring the size of the internal free-buffer queue. It detects that it is becoming congested when there are fewer than 256 buffers on the free queue(out of 1M capacity). At that time, the switch prevents frames from entering the device by forcing a collision indication on all half-duplex ports (except for the ports on which the switch is transmitting). When the switch has transmitted some of the backlog from its buffer, and the available free-buffer queue increases to more than256 spaces, forced collisions cease, and frames can again enter the switch. (The 256 buffer threshold ensures that all ports can receive and complete a maximum-length frame that may be in process.