GarrettCom Connecting the Console Terminal to Magnum 6K32T Management, Console DB-9 Port

Models: Magnum 6K32T

1 67
Download 67 pages 11.54 Kb
Page 42
Image 42

Magnum 6K32 & 6K32T Managed Switch

Installation and User Guide (12/05)

Step 3. Remove 6KPM Card

Carefully and gently pull out the daughter board from the latching connectors, using both hands, gripping the board near the latch-up connectors as shown in Fig. 3.5.3b . If the

now empty slot is to remain unused, be sure to install a 6KPM-BLNK face plate cover.

Figure 3.5.3b:

Removing a

6KPM Card

Follow the step 8 to complete the process successfully.

NOTE:1. If the modular slot has not being used and moved to other unit, the empty slot must be covered with Blank cover, to maintain proper air-inflow inside the unit and keep off from dust and other unavoidable substance, otherwise can cause a failure in the Switch.

2.If the PM module in the modular slot is not being installed properly or loose in connection, the MNS-6K management software will not boot-up properly and a error will generate as –{ failed to read register device type (offset 0x1600) on slot “A or B or C or D”}, whichever the slot has been used.

3.Always boot-up the Switch after any new module installation on modular slot to confirm the successful installation, before placing the chassis cover.

3.6Connecting the Console Terminal to Magnum 6K32T (Management)

Use a DB-9 “null modem” cable to connect the Magnum 6K32T Console Port (the RS-232 port on the 6K32T Switch) to the your PC, so that your PC becomes the 6K32T’s Console Terminal.

Note: The DB-9 cable does not include with the 6K32T unit package.

Console (DB-9)

Port

CONSOLE

PORT

O

OF

Rear View of Magnum 6K32T

www . GarrettCom . com

36

Page 42
Image 42
GarrettCom user manual Connecting the Console Terminal to Magnum 6K32T Management, Console DB-9 Port, Remove 6KPM Card