GarrettCom Magnum 6K32T user manual Relay Alarm Contact Optional, Per-port MDI or Mdix on RJ-45

Models: Magnum 6K32T

1 67
Download 67 pages 11.54 Kb
Page 9
Image 9

Magnum 6K32 & 6K32T Managed Switch

Installation and User Guide (12/05)

For (Optional) DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options (for continuity of operation when either of the DC input sources are interrupted), see Appendices B and C.

Relay Alarm Contact (Optional)

The Alarm Contact option is offered as a configuration option. The alarms can be initiated through two normally closed Form-C contacts, one loss of power alarm and one software alarm through user selectable software traps.

Per-port MDI or MDIX on RJ-45

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45 ports., and eliminate the use of cross-over cable between the devices. Also port-specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed using software commands.

Agency Approvals

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A NEBS L3 and ETSI Compliant for Carrier Central Offices

IEEE P1613 Environmental Standard for Electric Power Substations. IEC61850 EMC and Operating Conditions Class C for Power Substations

Warranty: Three years, return to factory

Made in USA

For a Configuration Guide, see the GarrettCom web site at

http://www.garrettcom.com/techsupport/insertion_guides/6K32Tcg.pdf

Email mktg@GarrettCom.com for additional details.

www . GarrettCom . com

3

Page 9
Image 9
GarrettCom Magnum 6K32T user manual Relay Alarm Contact Optional, Per-port MDI or Mdix on RJ-45, Agency Approvals