Magnum 6K32 & 6K32T Managed Switch

Installation and User Guide (12/05)

reversed while the Switch is operating from the other source.

e)The Switch will not receive power (and will not work) when both inputs are simultaneously absent or are both incorrectly connected.

C5.0 INSTALLATION

This section describes the proper connection of the -48VDC, 24VDC and 125VDC dual source leads to the -48VDC, 24VDC 7 125VDC power terminal block on the Magnum 6Ks Switch (shown in Figure )

The -48VDC terminal block on the Magnum 6K32T Switch, as shown in Fig C5.0 is

located on the right rear of the unit and

 

 

 

is equipped with five (5) screw-down

A+ A-

B- B+

 

lead posts. If it is the reverse model it

 

 

 

is located on the left rear. The primary

 

 

 

terminals are identified as positive

 

 

 

(A+), negative (A-), and the secondary

 

36-70VDC

 

power terminals as negative (B-),

36-70VDC

GND

 

 

 

positive(B+). The chassis “earth” or ground (GND) is a threaded post with a #6 nut. The Dual Source terminal block for the 24VDC and 125VDC are similar.

Figure C5.0: -48VDC Dual-Source, wiring connections to the External Terminal Block on a Magnum 48VDC with Dual-Source option

Note: The GND should be hooked up first. The6K32T unit has a floating ground, so the user may elect to Ground either + or = terminal to suit the customer’s use.

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.

The connection procedure is straightforward. Simply connect the DC leads to the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely tightened.

The 24VDC and 125VDC terminal block on Magnum 6K32T & 6K32’s is similar to that described in the –48VDC information above.