Magnum 6K32 & 6K32T Managed Switch

Installation and User Guide (12/05)

Fiber connector types supported:

 

ST-type (twist-lock)

 

SC-type (snap-in)

 

MTRJ-type Small Form Factor (SFF)

 

LC-type Small Form Factor (SFF)

 

GBIC modules

 

LEDs: Per Port

LK: Steady ON when media link is operational

ACT: ON with receiver port activity

FDX/HDX: ON = Full-Duplex Mode OFF = Half-Duplex Mode

100/10: ON = 100Mbps speed OFF = 10 Mbps

Operating Environment

UL 60950 “Component Parts” temp. ratings: 130° F (55°C)

IEC 60068 “Type Test” ratings:- -40°to 185°F (-40°to 85°C)

Ambient Relative Humidity: 5% to 95% (non-condensing)

Altitude: -200 to 13,000 ft. (-60 to 4000m)

Conformal Coating (Humidity Protection) option: Request quote

Packaging

Enclosure: Rugged High strength metal. Suitable for stand-alone or rack-mounting

Dimensions: 1.70in. H x 17.0in. W x 9.0in. D 4.32cm H x 43.2cm W x 22.9cm D

Cooling method: Fan cooled, @ 3@ 7 cfm ea.

Management Console connector

DB-9 for RS-232null-modem “ cable (sometimes called an X-modem cable)

Power Supply (Internal)

AC Power Connector: IEC-type, male recessed at rear of chassis,

with adjacent manual ON-OFF switch (optional if no Alarms Cont.) Input Voltage: 100 to 240 VAC (auto-ranging)

Input Frequency: 47 to 63 Hz (auto-ranging)

Power Consumption: 45 watts max (with fiber module)

30watts for a fully-loaded copper only model

Fuse required for replacement- 1 Amps

DC Power Supply (Options)

-48VDC Power Input Voltage : -36 to -70 VDC

Fuse Required – 2Amps

24VDC Power Input Voltage : 20 to 40VDC

Fuse Required – 3Amps

125VDC Power and 100VDC Input Voltage : 88 to 300VDC

Fuse Required – 1Amps

Std. Terminal Block : “ -, GND, + ”

Power Consumption: same as for AC models, see above

Warning- All the fuse replacment must be replaced with same value.

www . GarrettCom . com

2

Page 8
Image 8
GarrettCom Magnum 6K32T user manual Fiber connector types supported, LEDs Per Port, Operating Environment, Packaging