ON-SCREEN DISPLAY

– Alarm display –

Alarm display : Alarm messages are displayed as shown below, when an operation error has occurred or when the unit is in a poor condition for operation. E.g., dirty head.

 

 

3 2 K C H – 1 / 2

 

 

0 m i n

A

 

 

 

 

 

 

 

 

H E A D C L E A N I N G R E Q U I R E D !

 

 

 

B

 

 

 

 

 

 

 

 

 

I N V A L I D

T A P E !

 

 

 

 

 

 

1 0 / 1 0 / 0 2

 

S T A N D B Y - O F F

 

 

1 2 : 0 0 : 0 0

T C R

0 2 : 0 0 : 0 0 : 0 0

 

 

 

 

 

 

 

 

 

 

Display at position A : Displays which show the state of the unit continues to be displayed here until the conditions are rectified.

Display

Contents

 

 

LOW VOLTAGE

The voltage of the DC input power is low. Continued operation will bring the unit to the

 

POWER OFF mode.

 

Displayed irrespective of the DISPLAY mode setting.

 

 

HEAD CLEANING

The video head is dirty. Please clean it with the dedicated head-cleaning tape.

REQUIRED!

(Page 8)

 

If the head is clogged, it will be detected in the PLAYBACK mode and displayed.

 

When the unit enters the STOP mode or the cassette is ejected, the display goes off.

 

Displayed irrespective of the DISPLAY mode setting.

 

 

NO DV SIGNAL

Despite DV connection, signals are not received.

 

Displayed when DISPLAY mode is set to ON/AUTO.

 

 

Display at position B : Messages indicating operation errors are displayed for about 3 sec- onds.

They are displayed when the DISPLAY mode is ON or AUTO.

Display

Contents

INVALID TAPE!

Data tapes for PC use or DVC PRO tapes has been inserted.

 

The cassette will be ejected.

 

 

LP TAPE!

The user attempts to play back a tape recorded in the LP mode.

 

This unit cannot record or play in the LP mode.

DV NOT CONNECT

DV connection is not done.

E-22

Page 22
Image 22
Panasonic VQT0C55 manual Alarm display