TROUBLE SHOOTING GUIDE

 

 

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

 

 

 

 

 

 

The control panel display does not

Laminator not connected to

Insert attachment plug into

 

illuminate when POWER ON/OFF

electrical supply

receptacle

 

is in the ON, marked “I”, position

 

 

 

 

 

Blown out fuse.

Check fuses.

 

Heat rollers do not turn when I

Feed table not properly installed.

Tilt feed table and properly replace

 

 

 

it.

 

Press the RUN button.

Pull E-Stop button

Pull out on the E-STOP push button.

 

Heat rollers only turn if I use the

Photo eye is blocked.

Disengage the footswitch mode.

 

“Footswitch”.

 

Clear nip area.

 

Laminated items exhibit curling.

Tension between the top and bottom

Adjust tension per section FILM

 

 

film. Roll is unequal.

TENSION.

 

 

Tension on top or bottom roll of film

Adjust tension per section FILM

 

 

is too film is too loose.

TENSION.

 

 

Bottom film roll may be improperly

Make sure bottom roll of film is

 

 

loaded.

around idler bar and that is the

 

 

 

normal operation position.

 

Adhesive deposited on heat rollers.

Top and bottom film webs not

Release heat and pull roller pressure,

 

 

aligned

align the rolls of film.

 

 

Laminate improperly loaded.

Adhesive (matte) side of laminate

 

 

 

film may be against the heat rollers.

 

 

 

Unweb and reload the film properly.

 

Unsatisfactory adhesion of laminate.

Speed setting too fast for type of

Lower speed setting.

 

 

material being laminated

 

 

 

 

Insufficient heat

Wait for “READY” indicator to

 

 

 

appear in the control panel display.

 

 

Laminate improperly loaded

Adhesive side of film must be facing

 

 

 

away from the heat rollers.

 

 

Heat rollers require cleaning.

Bottom roll of film not threaded

 

 

 

behind the idle bar.

 

 

Laminated item unsuitable for

Clean heat rollers per procedure in

 

 

adhesion.

section CARING FOR THE GBC

 

 

 

3064 WF LAMINATOR. Item may

 

 

 

be dirty or may have non porous

 

 

 

surface that is extremely difficult to

 

 

 

laminate.

SERVICE AGREEMENT

GBC’s Equipment Maintenance Agreement will insure the quality performance and long life built into your laminator.

A service charge for travel time, labor and parts may be incurred for each out of warranty service call. GBC’s Equipment Maintenance Agreement

Decreases these expenses and protects your valuable investment. GBC offers several types of agreements to suit your needs and budget. To contact

GBC write to:

 

 

GBC NATIONAL SERVICE

IN CANADA:

GBC NATIONAL SERVICE

ONE GBC PLAZA

 

49 RAILSIDE ROAD

NORTHBROOK, IL 60062 U.S.A.

 

DON MILLS, ONTARIO

 

 

M3A 1B3

General Binding Corporation

 

 

One GBC Plaza

 

 

Northbrook, IL 60062-4195

 

 

®

 

 

 

 

 

© 200 6 General Binding Corporation

Page 38

Page 38
Image 38
GBC 1264WF, 1244WF operation manual Tension, Service Agreement