4.0 Installation

Spartan Operation and Maintenance Manual

4.0 Installation

GBC Films Group is committed to a program of ongoing product improvement. As a result, we are providing these instructions so that you can insure that your new Spartan Laminator is properly and securely unpacked, moved and installed.

Before a Spartan Laminator can be installed, there are a few requirements that must be met. Make certain that each of the requirements listed in the following pre- installation checklist are met before beginning installation.

CAUTION: Failure to follow the pre-installation check list can result in damage to the laminator.

WARNING: The operating environment must be free of dust, flammable liquids and vapors. You can be injured by inhaling chemical vapors.

WARNING: Vapor build up or stored flammable liquids can cause a fire. Excessive dust can damage the laminator.

CAUTION: Do not locate the laminator where air can blow directly on the machine. The air flow can cool the rollers unevenly and result in poor quality output.

4.1 Pre-installation

Are the doorways and hallways wide enough for the laminator to be moved to the installation site?

Is there ample room for the laminator?

A work area must be established that allows for unrestricted movement around the laminator and provides space for efficient material flow. Figure

4.1.4and Figure 4.1.5 illustrates a typical machine area layout.

Is the environment appropriate for the laminator?

The laminator requires a clean, dust and vapor free environment to operate properly. It must not be located where there is air blowing directly on the machine.

Have you contacted a certified electrician to install a receptacle for the laminator ensuring that adequate power is being supplied and correct circuit breaker?

US and Canada: The laminator requires 230- 240 vac, 60 Hz, 15 amps, single phase

Figure 4.1.1 Connections-Spartan US

N E M A 6 - 15P

N E M A 6 - 15R

Europe: The laminator requires 230-240, 50 Hz 16 amps, single phase

Figure 4.1.2 Connections-Spartan Europe

16 receptacle

16 p lu g