INSTALLING THROUGH THE WALL

Installation Instructions

INSTALLING THROUGH THE WALL

Read these instructions completely and carefully.

1PREPARE OPENING IN WALL

Make certain a wall receptacle is

available close to the hole location or make arrangements to install a receptacle.

The cord length for the 115-volt models is 72to the right and 47to the left.

For the 230/208-volt models the cord length is 65to the right and 39to the left.

2SUPPORT REQUIREMENTS FOR AIR CONDITIONER

The air conditioner wall case may be installed with 1/4min. extension out from the inside wall or with 1/4min. extension out from the outside wall.

The finished sides of the opening should be structural wall members.

Lintel – Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening. Do not allow the wall case to be used in lieu of a lintel.

Flashing – Install flashing (drip rail) as shown to prevent water from dripping inside the wall and down the outside of the building.

Brick veneer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lintel angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(if required)

 

 

 

 

 

 

 

Plaster

 

 

 

 

 

 

 

Caulking

 

 

 

 

 

 

 

line

(on all 4

 

 

 

 

 

 

 

 

sides on the

 

 

 

 

 

 

 

Trim

outside of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

molding

the case)

 

 

 

 

 

 

 

 

 

 

 

Caulking

 

(if desired)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(above &

 

Room side

 

 

 

 

 

below

 

 

 

 

 

 

 

 

 

 

 

 

 

the

 

 

 

 

 

 

 

flashing)

 

 

Flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(drip rail)

 

 

 

 

 

 

 

 

1/4min. extension 1PREPARE OPENING IN WALL inside the wall from

the trim molding

3

SUPPORT REQUIREMENTS FOR AIR CONDITIONER

Mortar between the case and the brick all around the case may be undercut at about 45° for improved caulking.

 

Inside

 

Top of case

 

Outside

Caulking

Undercut

 

mortar

15

Page 15
Image 15