ge.com

Safety

Cool Mode

Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase / Decrease pads to set the desired temperature between 64°F and 86°F in 1°F increments.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

Cooling Descriptions

For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.

For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.

For Quieter & Nighttime Cooling—Select the Cool mode and Low fan with a middle set

temperature.

Do Not Operate in Freezing Outdoor Conditions

Instructions

Instructions

Operating

NOTE: If the air conditioner is off and is then turned on

This cool-only air conditioner was not designed for

while set to a Cool setting or if turned from a fan setting

freezing outdoor conditions. It must not be used in

to a Cool setting, it may take approximately 3 minutes

freezing outdoor conditions.

for the compressor to start and cooling to begin.

 

Energy Saver Mode

Controls the fan.

ON—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.

OFF—The fan runs all the time, while the compressor cycles on and off.

Care and Cleaning

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan

entered. The room temperature will appear

speed to provide air circulation and filtering

in the display.

without cooling. Since fan only settings do not

NOTE: Auto Fan Speed cannot be used when in the

provide cooling, a Set temperature cannot be

Fan Only Mode.

 

Auto Fan Speed

Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.

If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.

NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.

Air Direction

Use the levers to adjust the air direction left and right.

Fingertip pressure on the louver banks adjusts the air direction up or down.

Troubleshooting

Consumer

Tips

Remote Control

To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

The remote control signal has a range of up to 20 feet.

Make sure nothing is between the air conditioner and the remote control that could block the signal.

Make sure batteries are fresh and installed

5

correctly as indicated on the remote control.

Support

Page 5
Image 5
GE AEM10 owner manual Care and Cleaning

AEM10 specifications

The GE AEM10 is a modern mobile generator that exemplifies the innovation and reliability that General Electric brings to the power generation industry. This generator is designed to meet the demands of various applications, including construction sites, emergency power supply, and outdoor events. Its advanced features and technologies set it apart from traditional generators, making it a popular choice among users seeking efficient and dependable energy solutions.

One of the main features of the GE AEM10 is its compact design, which allows for easy transportation and placement in diverse environments. Weighing significantly less than many comparable models, it can be easily moved by a small crew and set up quickly, reducing downtime and increasing productivity on job sites. The generator's rugged build and weather-resistant enclosures ensure it can withstand harsh conditions, making it suitable for both indoor and outdoor use.

Equipped with a powerful and fuel-efficient engine, the AEM10 offers reliable power output without compromising on performance. It features a user-friendly control panel that displays critical information in real-time, including power output, fuel level, and run time. This transparency allows operators to manage their energy consumption effectively and avoid unnecessary interruptions.

In terms of technology, the GE AEM10 incorporates cutting-edge digital monitoring systems that enhance operational safety and efficiency. The inclusion of advanced automatic voltage regulation ensures stable and clean power delivery, protecting sensitive equipment from voltage fluctuations. Furthermore, the generator's low emissions design aligns with global standards for environmental safety, reducing its ecological footprint.

Another notable characteristic of the AEM10 is its adaptive load management capability, which allows it to adjust power output based on real-time demand. This feature not only optimizes fuel usage but also extends the life of the generator, minimizing wear and tear during operation.

In summary, the GE AEM10 is a state-of-the-art mobile generator that combines portability, reliability, and advanced technology. Its compact design, powerful performance, and innovative features make it an ideal choice for a wide range of applications, ensuring that users can count on it for both everyday and emergency power needs. Whether for commercial, industrial, or recreational use, the AEM10 stands out as a leader in the mobile generator market.