GE GNPR40L, GNPR48L Sanitizing Procedures, Installation Instructions, Specifications/Dimensions

Models: GNPR48L GNPR40L

1 36
Download 36 pages 15.31 Kb
Page 15
Image 15
SANITIZING PROCEDURES

Installation Instructions

SANITIZING PROCEDURES

To complete the installation, do the following sanitizing procedures.

Care is taken at the factory to keep your water softener clean and sanitary. Materials used to make the softener will not infect or contaminate your water supply and will not cause bacteria to form or grow. However, during shipping, storage, installation and operation, bacteria could get into the softener. For this reason, sanitizing as follows is suggested when installing.

NOTE: Sanitizing is recommended by the Water Quality Association for disinfecting.

1.Be sure to complete all installation steps, including programming the control.

2.Pour about 3/4 oz. (112 tablespoons) of common 5.25% unscented household bleach (Clorox, Linco, Bo Peep, White Sail, Eagle, etc.) into the brinewell. Refer to illustration on page 5.

3.IMPORTANT: Press and hold for 3 seconds the faceplate REGEN button to start an immediate regeneration. The indicator light will alternate between TIME OF DAY and REGEN TIME REMAINING. The bleach will be drawn through the water softener, and out the drain. This process takes approximately 3 hours.

4.If, after sanitization, water from the house faucet tastes salty or has a slight color, this is a preservative from the resin tank. Turn on the cold soft water faucets and drain for a few minutes or until clear.

NOTE: When the sanitizing regeneration is over,

all remaining bleach is flushed from the conditioner and your house COLD water supply is fully soft immediately. However, your water heater is filled with hard water and as hot water is used, it will refill with soft water. When all the hard water is replaced in the water heater, hot only and mixed hot and cold water will be fully soft. If you want totally soft water immediately, after the above regeneration, drain the water heater until the water runs cold.

To complete the installation, do the following sanitizing procedures.WARNING: If you do drain the water heater, use extreme care as the hot water could cause burns. Turn the water heater off prior to draining.

SPECIFICATIONS/DIMENSIONS

GNPR40L

GNPR48L

 

Resin Tank Size

 

10x44

12x48

 

 

 

 

 

 

Resin Volume

 

1.25 ft3

1.50 ft3

 

Refill Controller

 

0.35 gpm

0.35 gpm

 

 

 

 

 

 

Backwash Controller

 

2.8 gpm

2.8 gpm

 

 

 

 

 

 

Brine Tank

Size

15x40

15x40

 

 

 

 

 

 

 

Capacity

350 lbs

350 lbs

 

 

 

 

 

 

Operation Temperature

Min.

34°

34°

 

 

 

 

 

 

 

Max.

100°F

100°F

 

Flow Rate

 

15.2 gpm

18.0 gpm

 

 

 

 

 

 

Pressure Drop

 

15.0 psi

15.0 psi

 

 

 

 

 

 

Maximum Flow to Drain

 

4.0 gpm

3.5 gpm

 

 

 

 

 

4014

15

 

1412

 

 

 

C

 

 

L

50

44

47

10

1514

C

L

These systems conform to WQA NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data.

*Testing was performed using pellet grade sodium chloride as the regenerant salt.

**Efficiency rating is valid only at the lowest stated salt dosage. These softeners were efficiency rated according to WQA NSF/ANSI 44.

***Extent of iron removal may vary with conditions. The capacity to reduce clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron. Use of Diamond Crystal® Red•Out® or Super Iron Out® will improve iron removal. Refer to Cleaning Iron Out of the Water Softening System section.

5414

5114

4014

48

 

15

12

15

Page 15
Image 15
GE GNPR40L, GNPR48L installation instructions Sanitizing Procedures, Installation Instructions, Specifications/Dimensions