Advanced programming and troubleshooting section.

WARNING: Advanced programming should only be performed by a qualified technician.

This section was designed for the use of water treatment professionals. Default settings are based on water conditions at a typical installation. Before making any changes, consult a water treatment professional, as incorrect settings may result in a system malfunction. Programming the control is not covered under the warranty.

To access advanced programming, simultaneously hold down the UP and DOWN buttons. This will allow you to enter advanced programming settings P6 through P19 (see table below).

Advanced Programming Parameters

 

 

 

Minimum

Units

 

 

Parameter

Description

Range

Increments

of Measure

 

Notes

 

 

 

 

 

 

P6

Refill controller

1–99

1

gpm

0.33 gpm, both models

 

 

 

 

 

 

P7

Brine draw value

1–99

1

Minutes

40L – 15 and 48L – 16

 

 

 

 

 

 

P8

Not used

N/A

N/A

N/A

N/A

 

 

 

 

 

 

P9

Backwash time

3–30

1

Minutes

Skip this parameter to accept the default

 

 

 

 

 

or enter a value.

 

 

 

 

 

 

P10

Slow rinse time

8–125

1

Minutes

GNPR40L = 67

 

 

 

 

 

GNPR48L = 83

 

 

 

 

 

 

P11

Fast rinse time

2–19

1

Minutes

Skip this parameter to accept the default

 

 

 

 

 

or enter a value.

 

 

 

 

 

 

 

P12

Units of measure

0–1

1

 

0

= U.S.

 

 

 

 

 

1

= Metric

 

 

 

 

 

Skip this parameter to accept the default

 

 

 

 

 

(U.S.).

 

 

 

 

 

 

 

P13

Clock mode

0–1

1

 

0

= 12-hour clock

 

 

 

 

 

1

= 24-hour clock

 

 

 

 

 

Skip this parameter to accept the default

 

 

 

 

 

(12-hour).

 

 

 

 

 

 

P14

Calendar override

0–30

1

days

0 = no calendar override

 

 

 

 

 

Skip this parameter to accept the default

 

 

 

 

 

(no override).

 

 

 

 

 

 

 

P15

Reserve type

0–3

1

 

0

= variable reserve

 

 

 

 

 

 

P16

Fixed reserve capacity

0–70

1

percent of capacity

Description depends on the value

 

or initial average value

 

 

 

entered for P15 (Reserve type). Skip this

 

 

 

 

 

parameter to accept the default.

 

 

 

 

 

 

 

P17

Operation type

0–1

1

 

0

= Not used

 

 

 

 

 

1

= 5-cycle counter current

 

 

 

 

 

 

 

P18

Salt/capacity change

0–1

1

 

0

= None

 

lock out

 

 

 

1

= salt/capacity change locked out

 

 

 

 

 

Skip this parameter to accept the default

 

 

 

 

 

(no lock out).

 

 

 

 

 

 

P19

Factory defaults

DO NOT

1

 

Loads in factory default values. DO NOT

 

 

CHANGE

 

 

CHANGE THIS PARAMETER.

 

 

 

 

 

 

 