6. TROUBLESHOOTING GUIDE
These troubleshooting procedures must be carried out only be a Factory Authorized Service Center or a local service company specializing in hotel and restaurant cooking appliances. The problems and possible solutions given below cover those most commonly encountered.
FOR DETAILED TROUBLESHOOTING AND
|
| PROBLEM |
|
|
| CORRECTIVE ACTION | |||||
Operator | hears click | sound | With the power switch “ON”: | ||||||||
when |
|
| the | temperature |
|
| |||||
controller dial is turned but | 1. | Manually reset the high temperature limit switch (push red button | |||||||||
vessel | remains | cold. |
| No |
| on the panel above the drain valve). See Figure | |||||
evidence | that elements | are | 2. | Check branch or main circuit breakers or fuses are not tripped or | |||||||
warming the vessel. |
|
|
| blown. | |||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check thermostat adjustment: | ||
Poor temperature control on | 1. | Check that the thermostat bulb/probe in the vessel has not been | |||||||||
| knocked loose from its operating position. It should be clamped to | ||||||||||
the | cold | side; |
| excessive |
| ||||||
|
| the 2nd element with 1/16 inch spacing. See Figure | |||||||||
time; | temperature | 2. | Place the sensing bulb of a high quality immersion thermometer | ||||||||
recovery |
| is |
| slow |
| or | |||||
|
|
|
| about | |||||||
inadequate | when | vessel | is |
| |||||||
| temperature controller dial to 350°F. | ||||||||||
loaded; or uneven heating. |
| ||||||||||
3. | Wait at least 30 minutes for the oil temperature to stabilize. | ||||||||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| 4. | If temperature is not within +/- 10°F of the dial setting, call | |
|
|
|
|
|
|
|
|
|
| service for a new operating thermostat/temperature controller. | |
|
|
|
|
|
|
|
|
| Check thermostat adjustment: | ||
Poor temperature control on | 1. | Check that the thermostat bulb/probe in the vessel has not been | |||||||||
| knocked loose from its operating position. It should be clamped to | ||||||||||
the | hot | side; |
| excessive |
| ||||||
|
| the 2nd element with 1/16 inch spacing. | |||||||||
temperature | overshooting | 2. | Place the sensing bulb of a high quality immersion thermometer | ||||||||
during | scorching; | ||||||||||
| about | ||||||||||
overheating; | or |
| high | limit |
| ||||||
|
| temperature controller dial to 350°F. | |||||||||
switch must be reset often. |
| ||||||||||
3. | Wait at least 30 minutes for the oil temperature to stabilize. | ||||||||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| 4. | If temperature is not within +/- 10°F of the dial setting, call | |
|
|
|
|
|
|
|
|
|
| service for a new operating thermostat/temperature controller. |
Figure
High Limit
Reset Switch
Drain
Valve Sensing Bulb in
Fryer Vessel
Figure