GE GNSF48A01 Problem, Possible Causes, What To Do, Salty tasting water, after installation

Models: GNSF48A01 GNSF39A01

1 36
Download 36 pages 13.69 Kb
Page 25
Image 25
What To Do

Problem

Possible Causes

What To Do

Salty tasting water

Insufficient backwash and

Increase backwash time. See the Service: Regeneration and

after installation

rinse time

Heavy Duty Backwash section.

 

 

 

 

Low water pressure

Check pressure; should be minimum 20 psi.

 

 

 

 

Restricted drain hose

Clean and reconnect hose.

 

 

 

Resin beads showing

Cracked distributor

Call for service.

up in drinking water

 

 

and sink

 

 

 

 

 

Sounds you might hear

Running water from the unit into

This is normal.

 

a drain

 

 

 

 

Water has air bubbles

Air in system after installation

Will go away after it runs for a while.

and is cloudy

 

 

 

 

 

Error Code on control

Wiring may have worked loose

Unplug transformer.

 

in control

Remove control cover, release clips on side.

 

 

 

 

Check for loose/incorrect wiring connections to electronic

 

 

board or switch. Reconnect as required.

 

 

Reassemble control cover.

 

 

Plug in Transformer.

 

 

Wait six minutes for Error Code to reappear.

 

 

If Error Code reappears call for service.

25

Page 25
Image 25
GE GNSF48A01 Problem, Possible Causes, What To Do, Salty tasting water, after installation, Heavy Duty Backwash section